User Manual Part 3

System Configuration
4-21
4. Specify the users who can read and optionally modify the SNMP-capable client.
Security Level Use the Security Level area to specify a security level of noAuth
(no authorization), AuthNoPriv (authorization without privacy), or
AuthPriv (authorization with privacy).
The NoAuth setting specifies no login authorization or encryption
for the user.
The AuthNoPriv setting requires login authorization, but no
encryption.
The AuthPriv setting requires login authorization and uses the
Data Encryption Standard (DES) protocol.
OID Use the OID (Object Identifier) area to specify a setting of All or
enter a Custom OID. Select All to assign the user access to all OIDs
in the MIB. The OID field uses numbers expressed in dot notation.
Passwords Select Passwords to display the Password Settings screen for
specifying authentication and password settings for an SNMP v3
user. The maximum password length is 11 characters. Use the
Authentication Algorithm drop-down menu to specify MD5 or
SHA1 as the authentication algorithm. Use the Privacy Algorithm
drop-down menu to define an algorithm of DES or AES-128bit.
When entering the same username on the SNMP Traps and
SNMP Access screens, the password entered on the SNMP Traps
page overwrites the password entered on the SNMP Access page.
To avoid this problem, enter the same password on both pages.
Access Use the Access pull-down list to specify read-only (R) access or
read/write (RW) access for a user. Read-only access permits a user
to retrieve
access point information, while read/write access
allows a user to modify
access pointsettings.