Operation Manual
20 
10. INSPECTION AND MAINTENANCE BEFORE RIDING   
  INSPECTION AND MAINTENANCE OF BATTERY   
y  This scooter is equipped with a maintenance-free type battery, so it is unnecessary to check or   
electrolyte.    Have your scooter checked by SYM Authorized Dealer or Franchised Dealer should any 
abnormality be found. 
y  Remove the battery terminals and clean if there is dirt or corrosion on them. 
Negative 
Positive 
NOTICE: 
Battery removal procedures are as follows: 
y First turn ignition switch “OFF,” then remove the negative cable screw and disconnect the negative 
cable, then remove the positive cable screw and positive cable and remove battery. 
y To install the battery, reverse the procedures of the removal of the battery. 
  CAUTION: 
y Keep the scooter’s battery clean.    If the battery’s posts are corroded and/or are covered with 
white powder clean them with warm water. 
y If there is obvious corrosion on the battery terminals, disconnect the battery cables and remove 
the corrosion with a steel brush. 
y If the battery needs to be replaced, replace with a same closed-type battery (Maintenance-Free). 
 CAUTION: 
y This scooter uses a sealed type (Maintenance-Free) battery; never remove the battery caps. 
y In order to prevent electrical leakage and self-discharge when the battery sits idle for long periods 
of time, remove the battery from scooter and store it in a well-ventilated and dimly lighted area.   
Store battery out of reach of children.    If the battery is to be kept on the scooter, disconnect the 
battery’s negative cable. 
y Replace the battery cables after cleaning and apply a thin coat of grease to the battery terminals 
when reconnecting the same. 