Installation Instructions
17. Electrical System
17-4 
Battery 
Removal 
Loosen 1 screw and remove the battery cover. 
Disconnect the negative cable terminal first, then 
the positive cable terminal. 
Remove the battery. 
Voltage Check 
Use the digital voltmeter to check the voltage of 
the battery. 
Voltage: 
Fully charged:  12.8V ↑ at 20℃ 
Undercharged:  Below 12.0 V at 20℃ 
 Warning 
y  Keep flames away while recharging. 
y  Charging is completely controlled by the 
ON/OFF switch on the charger, not by 
battery cables. 
Charging 
Connect the positive terminal (+) of the charger to 
the battery positive terminal (+). 
Connect the negative terminal (-) of the charger to 
the battery negative terminal (-). 
 Standard Maximum 
Charging current  1.2A    17A 
Charging time  10 hr  0.5 hr 
 Warning 
y  Keep flames away while recharging. 
y  Charging is completely controlled by the 
ON/OFF switch on the charger, not by 
battery cables. 
 Caution 
y Never rapid charge the battery unless in 
emergency. 
y Verify the battery is recharged with current 
and duration prescribed above. 
y Large current and fast time to charge will 
render damage to the battery. 
When installing the battery, coat the cable terminal 
with grease. 
To this chapter contents 