Installation Instructions
12. Cooling System 
12-5 
Change of coolant 
 Warning 
y  Never attempt to carry out service work on 
the cooling system unless the engine is 
completely cooled down, otherwise, you may 
get scalded. 
Remove the reserve tank cap cover, and then 
remove tank cap. 
Place a water pan under the water pump; loosen 
the drain bolt to drain out the coolant. 
Reinstall the drain bolt. 
Refilling system with coolant and bleeding the air 
bubbles. 
y  Run the engine, and remove by-pass pipe. 
y  Check by-pass hole whether has the air bubble 
to emit. 
y  If emits without the air bubble, only has the 
coolant to flow out, then backflow pipe joint on, 
engine flameout. 
y  Remove radiator filler cap. 
y  Starts the engine, inspects does not have the air 
bubble in the radiator coolant, also the coolant 
liquid level is stable. 
y  Stop the engine. Add coolant to proper level if 
necessary. 
y  Screw and tighten up the radiator filler cap. 
 Caution 
y  In order to avoid the water tank rusting, please 
do not use the unclear trade mark refrigerant.
Coolant recommended: SYM Bramax radiator 
agent. 
Concentration: 50%
Drain bolt
By-pass pipe
Reserve tank cap
To this chapter contents 