Specification Sheet
Photometric Data (UNV/347V)
WALPAK2N/030UNV750/NC
Isofootcandle Lines at
15' Mounting Height
WALPAK2N/050UNV750/NC
Isofootcandle Lines at
18' Mounting Height
WALPAK2N/075UNV750/NC
Isofootcandle Lines at
20' Mounting Height
Mounting
Height
12' 15' 18' 20' 22'
Multiplier
1.56 1.00 0.69 0.56 0.46
For other mounting heights apply the following multipliers:
Mounting
Height
15' 18' 20' 22' 25'
Multiplier
1.44 1.00 0.81 0.67 0.52
Mounting
Height
15' 18' 20' 22' 25'
Multiplier
1.78 1.23 1.00 0.83 0.64
WALPAK3N/105UNV740/NC
Isofootcandle Lines at
25' Mounting Height
Mounting
Height
22' 25' 30' 32' 35'
Multiplier
1.29 1.00 0.69 0.61 0.51
Ordering Information
Item Ordering Power Input Color Temp Total Fixture BUG
Number Abbreviation (W) Voltage CRI (CCT) Distribution Lumens LPW* DLC** Rating Options
74202 WALPAK1N/050UNV750/NC/BZ 50 120-277V >70 5000K Type IV 5300 108 – B1-U4-G3 –
74217 WALPAK1N/050UNV740/NC/BZ/P 50 120-277V >70 4000K Type IV 5000 104 – B1-U4-G3 Photocontrol
72996 WALPAK1N/040347750/NC/BZ 40 347V >70 5000K Type IV 4300 102 – B1-U4-G3 –
72997 WALPAK1N/055347750/NC/BZ 55 347V >70 5000K Type IV 6300 108 – B1-U4-G3 –
72998 WALPAK1N/080347750/NC/BZ 80 347V >70 5000K Type IV 9400 120 Std B1-U5-G5 –
74386 WALPAK2N/030UNV740/NC/BZ 30 120-277V >70 4000K Type IV 3400 122 Prm B1-U4-G3 –
74482 WALPAK2N/030UNV750/NC/BZ 30 120-277V >70 5000K Type IV 3500 125 Prm B1-U3-G3 –
74485 WALPAK2N/050UNV740/NC/BZ 50 120-277V >70 4000K Type IV 5500 113 Std B1-U4-G3 –
74486 WALPAK2N/050UNV750/NC/BZ 50 120-277V >70 5000K Type IV 5600 116 Std B1-U4-G3 –
74489 WALPAK2N/075UNV740/NC/BZ 75 120-277V >70 4000K Type IV 8900 118 Std B1-U5-G5 –
74490 WALPAK2N/075UNV750/NC/BZ 75 120-277V >70 5000K Type IV 9200 121 Std B1-U5-G5 –
74387 WALPAK2N/030UNV740/NC/BZ/P 30 120-277V >70 4000K Type IV 3400 122 Prm B1-U4-G3 Photocontrol
74483 WALPAK2N/030UNV750/NC/BZ/P 30 120-277V >70 5000K Type IV 3500 125 Prm B1-U3-G3 Photocontrol
74487 WALPAK2N/050UNV740/NC/BZ/P 50 120-277V >70 4000K Type IV 5500 113 Std B1-U4-G3 Photocontrol
74488 WALPAK2N/050UNV750/NC/BZ/P 50 120-277V >70 5000K Type IV 5600 116 Std B1-U4-G3 Photocontrol
74491 WALPAK2N/075UNV740/NC/BZ/P 75 120-277V >70 4000K Type IV 8900 118 Std B1-U5-G5 Photocontrol
74492 WALPAK2N/075UNV750/NC/BZ/P 75 120-277V >70 5000K Type IV 9200 121 Std B1-U5-G5 Photocontrol
74528 WALPAK3N/105UNV740/NC/BZ 105 120-277V >70 4000K Type IV 12500 119 Std B3-U4-G4 –
74529 WALPAK3N/105UNV750/NC/BZ 105 120-277V >70 5000K Type IV 12400 118 Std B2-U4-G5 –
74499 WALPAK1N/050UNV740/NC/BZ/E (MTO) 50 120-277V >70 4000K Type IV 5000 104 Std B1-U4-G3 Emergency Battery Backup
74500 WALPAK1N/050UNV750/NC/BZ/E (MTO) 50 120-277V >70 5000K Type IV 5300 108 Std B1-U4-G3 Emergency Battery Backup
60145 WALPAK3N/105UNV740/NC/BZ/P (MTO) 105 120-277V >70 4000K Type IV 12,500 119 Std B3-U4-G4 Photocontrol
60146 WALPAK3N/105UNV750/NC/BZ/P (MTO) 105 120-277V >70 5000K Type IV 12,400 118 Std B2-U4-G5 Photocontrol
*LPW per LM79 report.
**Prm for DLC Premium; Std for DLC Standard
***Standard lead time for MTO is 1-2 weeks.
For further information and to learn more about utility rebates, contact your local SYLVANIA sales representative.
2
1
.5
.2
.1
0 1 2 3 4
0
1
2
3
4
2
1
.5
.2
.1
0 1 2 3 4
0
1
2
3
4
2
1
.5
.2
.1
0 1 2 3 4
0
1
2
3
4
0 1 2 3 4
0
1
2
3
4
2
1
.5
.2
.1
Options Information
Emergency Battery Backup:
Activates when normal power supply to fixture fails, providing a minimum of 500 lumens for at least 90 minutes.