Specification Sheet
Photometric Information
Zonal Lumen Distribution
Zone Lumens % Fixture
0-30 305.6 41.3
0-40 462.6 62.5
0-60 668.3 90.3
60-90 71.5 9.7
0-90 739.8 100.0
90-180 0.0 0.0
0-180 739.8 100.0
Spacing to Mounting Height Ratio
Spacing Criteria (0-180°) 1.04
Spacing Criteria (90-270°) 1.08
Spacing Criteria (Diagonal) 1.12
110 cd
330 cd
220 cd
440 cd
0°
30°
60°
90°
0 cd
Polar Chart Illuminance at Distance
Maximum Intensity: 567 cd
2 ft
4 ft
6 ft
8 ft
10 ft
12 ft
Beam Diameter
3.2 ft
6.
4 ft
9.6 ft
12.8 ft
16.1 ft
19.3 ft
Illuminance
3.0
fc
4.4 fc
6.8 fc
12.2 fc
27.4
fc
109.5 fc
Horiz. Spread: 77.5°
Vert. Spread: 77.6°
Center
Edge
26.0 fc
H
V
6.5 fc
2.9 fc
1.6 fc
1.0 fc
0.7
fc
3.2 ft
6.4 ft
9.6 ft
12.3 ft
16.1 ft
19.3 ft
Zone
Lumens
% Fixture
0-30
393.6
43.2
0-40
589.4
64.7
0-60
828.9
91.0
60-90
81.7
9.0
0-90
910.6
100.0
90-180
0.0 0.0
0-180
910.6
100.0
Spacing Criteria (0-180
°
)
1.02
Spacing Criteria (90-270
°
)
1.04
Spacing Criteria (Diagonal)
1.10
Maximum Intensity: 438 cd
ULTRA RT6 700
150 cd
450 cd
300 cd
600 cd
0°
30°
60°
90°
0 cd
Polar Chart
Illuminance at Distance
Zonal Lumen Distribution
Zone Lumens % Fixture
0-30 393.6 43.2
0-40 589.4 64.7
0-60 828.9 91.0
60-90 81.7 9.0
0-90 910.6 100.0
90-180 0.0 0.0
0-180 910.6 100.0
Spacing to Mounting Height Ratio
Spacing Criteria (0-180°) 1.02
Spacing Criteria (90-270°) 1.04
Spacing Criteria (Diagonal) 1.10
Maximum Intensity: 567 cd
2 ft
4 ft
6 ft
8 ft
10 ft
12 ft
Beam Diameter
3.1 ft
6.
2 ft
9.3 ft
12.4 ft
15.5 ft
18.6 ft
Illuminance
3.9
fc
5.7 fc
8.9 fc
15.8 fc
35.4
fc
141.8 fc
Horiz. Spread: 75.1°
Vert. Spread: 75.5°
Center
Edge
35.0 fc
H
V
8.8 fc
3.9 fc
2.2 fc
1.4 fc
1.0
fc
3.1 ft
6.1 ft
9.2 ft
12.3 ft
15.4 ft
18.4 ft
Zone
Lumens
% Fixture
0-30
393.6
43.2
0-40
589.4
64.7
0-60
828.9
91.0
60-90
81.7
9.0
0-90
910.6
100.0
90-180
0.0 0.0
0-180
910.6
100.0
Spacing Criteria (0-180
°
)
1.02
Spacing Criteria (90-270
°
)
1.04
Spacing Criteria (Diagonal)
1.10
Maximum Intensity: 567 cd
ULTRA RT6 900
175 cd
525 cd
350 cd
700 cd
0°
30°
60°
90°
0 cd
Polar Chart
Illuminance at Distance Zonal Lumen Distribution
Zone Lumens % Fixture
0-30 503.0 39.0
0-40 61.0 61.0
0-60 1163.0 91.0
0-90 1275.0 100.0
90-180 0.0 0.0
0-180 1275.0 100.0
Spacing to Mounting Height Ratio
Spacing Criteria (0-180°) 1.14
Spacing Criteria (90-270°) 1.14
Spacing Criteria (Diagonal) 1.18
Maximum Intensity: 567 cd
2 ft
4 ft
6 ft
8 ft
10 ft
12 ft
Beam Diameter
Illuminance
4.8
fc
6.8 fc
10.7 fc
19 fc
42.8
fc
171 fc
Horiz. Spread: 75.1°
Vert. Spread: 75.5°
Center
Edge
38.4 fc
9.6 fc
4.3 fc
2.4 fc
1.5 fc
1.1
fc
3.4 ft
6.7 ft
10.4 ft
13.4 ft
16.8 ft
20.1 ft
Zone
Lumens
% Fixture
0-30
503
39
0-40
61
61
0-60
1163
91
0-90
1275
100
90-180
0.0
0.0
0-180
1275 100
Spacing Criteria (0-180
°
)
1.02
Spacing Criteria (90-270
°
)
1.04
Spacing Criteria (Diagonal)
1.10
Maximum Intensity: 695 cd
ULTRA RT6 1200
/sylvania
/sylvania
© 2017 LEDVANCE
LEDVANCE LLC
200 Ballardvale Street
Wilmington, MA 01887 USA
Phone 1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
SYLVANIA and LEDVANCE are registered trademarks.
All other trademarks are those of their respective owners.
Licensee of product trademark SYLVANIA in general lighting.
Specifications subject to change without notice.