Installation Guide
Table Of Contents
4. Re-attach the front cover of the fixture and re-connect the quick connect connector (Fig. 2-4A).
Make sure the door gasket is properly seated around the perimeter. Close front cover and secure by
tightening the two screws loosen on step 1. (Fig 2-4B). Installation is complete. Turn power on.
EMERGENCY BATTERY BACKUP WIRING:
If your product includes emergency battery backup please use the following electrical diagram as a
reference.
Fig 4A
Wiring diagram for the emergency battery back-up (Fig4A).
CLEANING AND MAINTENANCE
• To maintain the fixture efficacy occasional cleaning of the outer lens surface may beneeded.
•Use a mild soap or detergent, which is essentially neutral pH (pH approximately 6 to 8), nonabrasive, and
which contains no chlorinated or aromatichydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipedry.
TROUBLE SHOOTING CHECKLIST: If luminaire does not work
– Check your power source.
– Check electrical connections.
Disable Photocell
-To disable, unplug the connector shown below highlighted with red arrow.