MSDS
SPECIAL FIRE FIGHTING PROCEDURES
In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other
positive pressure mode.
UNUSUAL FIRE AND EXPLOSION HAZARDS
Above flash point, vapor-air mixtures are explosive within flammable limits noted above. Contact with strong oxidizers may cause fire or explosion. Vapors can flow along
surfaces to distant ignition source and flash back. Sensitive to static discharge.
SECTION V - HEALTH HAZARD DATA
EFFECTS OF OVEREXPOSURE - Conditions to Avoid Red skin, burning eyes, nausea, possible dizziness
THRESHOLD LIMIT VALUE PERMISSIBLE EXPOSURE LIMIT
200 ppm (TWA), 400 ppm (STEL)
OTHER LIMITS
N/A
PRIMARY ROUTES OF ENTRY
❍
INHALATION : Vapors Irritate the respiratory tract
❍
SKIN CONTACT : rash or irritation
❍
EYE CONTACT : redness or irritaion
❍
INGESTION : nausea or vomiting
EMERGENCY AND FIRST AID PROCEDURES
Inhalation - Remove to fresh air. If irritation persist medical attention.
Eyes – rinse with water for 15 minutes, get medical attention if irritation persist
Skin – rinse with plenty of water. Get medical attention if irritation persist
Ingestion – DO NOT INDUCE VOMITING ! Drink plenty of water, get medical attention
SECTION VI - REACTIVITY DATA
STABILITY UNSTABLE No CONDTIONS TO AVOID Heat, Light and Ignition
STABLE
Yes
INCOMPATIBILITY (materials to avoid)
Heat, flame, strong oxidizers, acetaldehyde, acids, chlorine, ethylene oxide, hydrogen-palladium combination, hydrogen peroxide-sulfuric acid combination, potassium tert-
butoxide, hypochlorous acid, isocyanates, nitroform, phosgene, aluminum, oleum and perchloric acid.
HAZARDOUS DECOMPOSITION PRODUCTS:
Carbon dioxide and carbon monoxide may form when heated to decomposition.
HAZARDOUS POLYMERIZATION MAY OCCUR
No
CONDITIONS TO AVOID none known
WILL NOT OCCUR
Yes
SECTION VII - SPILL OR LEAK PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Rinse with plenty of water. Will be slippery
WASTE DISPOSAL METHOD
Dispose of container and unused contents in accordance with federal, state and local requirements.
SECTION VIII - SPECIAL PROTECTION INFORMATION
RESPIRATORY PROTECTION none needed when used as directed in well ventilated area.
VENTILATION Well ventilated, no mechanical ventilation needed when used as
directed.
SPECIAL: N/A