Instructions
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE. 1528594_V1_0217_02_VTP_m_en
Preparation
Type labels in different languages are included in the package. Stick the language label in your
language over the German language label on the daily timer switch.
Getting Started, Use
Follow the safety instructions and the other information in this operation manual!
• Plug the daily timer switch into a regular earthed mains socket (wall socket).
Important!
Upon delivery, the internal NiMH battery securing the settings in case of power cut
(or when plugging the daily timer switch) is empty.
The power supply for the LCD display is buffered with the NiMH battery, which can
result in non-optimal display contrast after start-up. After about 30 hours, the NiMH
battery should be charged to the extent that the display contrast has become nor-
mal.
The NiMH battery is fully charged after about 48 hours; when unplugging the daily ti-
mer switch from the mains voltage (e.g., during storage), the settings / programming
is maintained at full charge for about max. 6 months.
Setting the time
Setting the hours:
• Hold the small „TIME“ button pressed and then set the hours by pressing the „HOUR“ button
(press the „HOUR“ button longer for quick adjustment).
• Release the „TIME“ button after setting the hours.
The clock display works always in the 12h mode. In the morning, „AM“ is shown at
the right bottom of the display, whereas „PM“ is displayed in the afternoon.
Setting the minutes:
• Hold the small „TIME“ button down and then set the minutes by pressing the „MIN“ button
(press the „MIN“ button longer for quick adjustment).
• Release the „TIME“ button after setting the minutes.
Programming the on/off time
The on/off time display is always in 12h mode. In the morning, „AM“ is shown at the
right bottom of the display, whereas „PM“ is displayed in the afternoon.
Therefore, make sure to set the on/off time for the correct 12-hour period when
programming!
Programming the switch-on time:
• Hold the „ON“ button down and then set the hours by pressing the „HOUR“ button or the
minutes by pressing the „MIN“ button. The „HOUR“ or „MIN“ button should be pressed longer
for a quick adjustment.
• Release the „ON“ button after programming the switch-on time.
Programming the switch-off time:
• Hold the „OFF“ button and then set the hours by pressing the „HOUR“ button or the minutes
by pressing the „MIN“ button. The „HOUR“ or „MIN“ button should be pressed longer for a
quick adjustment.
• Release the „OFF“ button after programming the switch-off time.
View switch on/off time
View switch on time:
• Briey press the „ON“ button, then the currently programmed switch on time will be shown
(bottom of the display will show „PROG ON“).
• To view the time once again, press the „TIME“ button briey (alternatively, you can also wait
a few seconds, without pressing a button).
View switch off time:
• Briey press the „OFF“ button, then the currently programmed switch off time will be shown
(bottom of the display will show „PROG OFF“).
• To view the time once again, press the „TIME“ button briey (alternatively, you can also wait
a few seconds, without pressing a button).
Display of the current switching state
Bottom of the display indicates the current switching state of the front socket or the connected
device:
„ON“ Front outlet / device switched on
„OFF“ Front outlet / device switched off
Reset
In order to reset the daytime timer, switch to the default settings and delete all programming,
press the countersunk button „RST“ briey. The display shows all the display segments, then
the daily timer switch is ready for operation.
Please note:
All settings and programming are lost upon reset!
Activating the lighting of the LC display/night light function
Use the „ “ button to switch the display light on or off.
The light can also be used as night light due to its large size and brightness.
Care and Cleaning
Before cleaning the product, disconnect the appliance from the daily timer switch. Disconnect
then the daily timer switch from the power supply by pulling it out of the mains socket.
Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these
could damage the housing or even impair operation.
Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable material and do not belong in the household was-
te. Dispose of an unserviceable product in accordance with the relevant statutory
regulations.
Technical Data
Operating voltage .................................230 V/AC, 50 Hz
Connection power .................................resistive load: max. 3680 W (230 V/AC, 16 A)
..............................................................inductive load: max. 690 W (230 V/AC, 3 A)
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Powered devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy-saving bulbs, etc.
Protection type ......................................IP20
Switch type ...........................................Relay (single-pole)
Socket with child protection ..................yes
Switching times per day ........................1x ON, 1x OFF
Shortest switching duration ..................1 min
Data retention ....................................... with an internal NiMH battery (max. approx. 6 months
with fully charged battery)
Ambient conditions ............................... Temperature 0 °C to +40 °C, air humidity 20% to 85%
relative, non-condensing
Dimensions ........................................... 133 x 70 x 80 mm (L x W x H, including plug)
Weight ..................................................200 g