7 Installation requirements
Installation height from the ground: min. 2.3 m
Distance between ceiling and product: min. 5 cm
The product must only be operated on mains voltage.
The product must be protected by a 10/16A fuse in the building’s fuse box. A ground
fault circuit interrupter must be installed before this (FI protective switch).
Install a switch to control the on/off state of the product. Distance between contact points
of polarity switch: min. 3 mm.
The air temperature must not exceed +45 °C.
Do not install the product in a wet or highly humid location.
For use with fireplaces that require a chimney in the room to be ventilated, sufficient air
intake must be provided for the use of the product as an exhaust fan.
Compliance
The installation of the product must comply with DIN VDE 0100-701. Observe the protec-
tion zones for rooms with bath or shower.
Make sure that rotating parts cannot be disturbed. Mount a suitable DIN 31001 compliant
protective grille, if necessary.
In commercial institutions, the accident prevention regulations of the employer’s liability
insurance association for electrical systems and operating facilities are to be observed.
Duct
Prevent backflow.
Make sure that no water can enter the suction duct. Install a suitable protection (ex-
ample: self-closing louver grills), if necessary.
For installations in flexible ducts, use suitable fastening clamps.
8 Wiring diagram
Motor
Brown wire
Blue wire
9 Cleaning and care
Important:
Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Clean the product with a dry, fibre-free cloth.
10 Disposal
This symbol must appear on any electrical and electronic equipment placed on
the EU market. This symbol indicates that this device should not be disposed of
as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
in our Conrad offices
at the Conrad collection points
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.
11 Technical data
Unit Value
Operating voltage V/AC 220 - 240
Operating voltage frequency Hz 50
Protection class Class II
Ingress protection IPX2
Cord length mm 420
Max. air temperature °C +45
Material ABS
Operating temperature °C 0 to +45
Operating humidity (non-condensing) % RH ≤85
Storage temperature °C 0 to +45
Storage humidity (non-condensing) % RH ≤85
Item no: 2616624
Unit Value
Power consumption W 12
Max. air volume m³/h 130
Motor speed min-1 2200
Max. noise emission (from 3 m) dB(A) 34
Required duct diameter mm 100
Dimensions (Ø x H) mm 104 x 88
Weight g 375
Item no: 2616625
Unit Value
Power consumption W 16
Max. air volume m³/h 240
Motor speed min-1 2000
Max. noise emission (from 3 m) dB(A) 34
Required duct diameter mm 125
Dimensions (Ø x H) mm 129 x 88
Weight g 475
Item no: 2616626
Unit Value
Power consumption W 18
Max. air volume m³/h 320
Motor speed min-1 1850
Max. noise emission (from 3 m) dB(A) 35
Required duct diameter mm 150
Dimensions (Ø x H) mm 154 x 108
Weight g 530
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2616624_2616625_2616626_V1_1022_jh_mi_en 18014399185406091-2 I3/O1 en