Instructions
27
c) Setting the Temperature
The temperature range is 5 to 50 °C, and the default temperature is 15 °C.
If the room temperature is 1 °C higher than the set temperature, heating will stop.
If the room temperature is 2 °C lower than the set temperature, heating will start.
• Press or to adjust the temperature in 1 °C increments.
- will ash on the LCD display after each adjustment.
- The temperature will be saved after 3 seconds of no action.
d) Adjust Heating Level
If the heater cannot achieve the set temperature or you would like to speed the process up, you may consider
increaseing the heating level.
• Press to adjust the heating level.
• The LCD will show the heating level (low , medium , high ).
Refer to section “15. Technical Data” for information about energy consumption.
e) Timer Function
Setting Shut-OFF Timer
If the heater is currently running, you can program a timer to stop heating after a set number of hours.
• Press to enter timer setting, will ash on the LCD display.
- Press or to set the number of hours (1 to 24).
- The hours will be saved after 3 seconds of no action.
• The LCD will show to indicate a shut-off timer has been set.
Setting ON Timer
If the main power switch is ON but the heater in standby mode (not heating), you can program a timer to start heating
after a set number of hours.
• Press to enter timer setting, will ash on the LCD display.
- Press or to set the number of hours (1 to 24).
- The hours will be saved after 3 seconds of no action.
• The LCD will show and to indicate that the ON timer has been set.
• You can cancel the timer by pressing .
f) Automatic Anti-Frost Function
• The main power switch should be in the ON position.
• If the room temperature is lower than 5°C, the heater will automatically start heating to prevent frost from forming.
The LCD will show .
• When the room temperature reaches 10°C, the heater will stop heating.