Instructions

Example 1: Single-use visitor code
Output #1 will be activated when the valid code is entered. The code can only be used once.
This means that the visitor can only access the premises once.
(a) (b) (c) (d) (e)
(a) Programming code for visitor code
(b) Memory slot number = 0 (choose from 0 - 9)
(c) "00" indicates a single-use code
(d) Visitor code = 1268
(e) Savesthecode(thelockwillbeeptwiceandthemiddleLEDwillashtwotimes)
Example 2: Visitor code with a time limit:
Thevisitorcodeisvalidfor a specied duration (01-99hours).Afterthisperiod,thecode
automatically becomes invalid.
Duringthespeciedperiod,thevisitorcanactivateoutput#1likeastandarduser.
(a) (b) (c) (d) (e)
(a) Programming code for visitor code
(b) Memory slot number = 2 (choose from 0 - 9)
(c) Time limit 03 = Code is valid for three hours (choose from 01 - 99 hours)
(d) Visitor code = 1378
(e) Savesthecode(thelockwillbeeptwiceandthemiddleLEDwillashtwotimes)
Deleting visitor codes:
(a) (b) (c)
(a) Programming code for visitor code
(b) Memory slot number = 2 (choose from 0 - 9)
(c) Deletesthecode(thelockwillbeeptwiceandthemiddleLEDwillashtwotimes)
88