g) Visitor code
Visitorcodesarespecialaccesscodesthatcanbeusedonceorforaspeciedperiod.Youcan
save up to 10 visitor codes.
• Single-use code: Output #1 will be activated when a valid visitor code is entered. The code 
can only be used once.
• Code with a time limit: The visitor code can be used an unlimited number of times during 
thespeciedtimeperiod(01-99hours).Afterthisperiod,thecodeautomaticallybecomes
invalid.
  For security reasons, all visitor codes are automatically deleted in the event of a power 
cut.
Saving visitor codes:
• The combination lock must be in programming mode (see section 12. a) for details).
• Enter programming code    .
• Enter one of the 10 available memory slot numbers ( ..... ).
• Choose the type of visitor code:
  Single-use code
  .....     Time limit of the visitor code in hours (01.....99 hours)
• Enter the desired 4 - 8 digit visitor code. 
 Important!
  In "Auto entry" mode (see section 12. m), all codes must be the same length (e.g. if 
the master code is 5 digits, the user codes must also be 5 digits). 
• Press the  buttontoconrmyourentry.Thecombinationlockwillbeeptwiceandthemid-
dleLEDwillashtwotimestoindicatethatthevisitorcodehasbeensaved.
87