Instructions
d) Superuser code
The superuser code allows you to manually enable outputs #1 and #2. It is not affected by time
restrictions or system locks.
It can also be used to permanently enable output #1.
Saving the superuser code:
• The combination lock must be in programming mode (see section 12. a) for details).
• Enter programming code .
• Enter a 4 to 8 digit code (e.g. ).
Important!
When the "Auto entry" feature is enabled (see section 12. m), all codes must be the
same length (e.g. if the master code is 5 digits, the user codes must also be 5 digits).
• Press the buttontoconrmyourentry.
• ThecombinationlockwillbeeptwiceandthemiddleLEDwillashtwotimestoindicatethat
the superuser code has been saved.
The existing superuser code will be overwritten.
Deleting the superuser code:
• The combination lock must be in programming mode (see section 12. a) for details).
• Enter programming code .
• Press the buttontoconrmyourentry.Thecombinationlockwillbeeptwiceandthemid-
dleLEDwillashtwotimestoindicatethatthesuperusercodehasbeendeleted.
Function 1: Enabling/disabling output #1 and #2
Enter the superuser code like a standard user code. The corresponding output will be enabled/
disabled (the superuser code will reset the enabled output if you have set a very long timer (see
section 12. h) for details).
Example: The Superuser-Code was set to "6789":
Enable/disable output #1
Enable/disable output #2
80