Data Sheet
Standard Setup and Test Procedure
In this section, a standard procedure for testing the performance of TransducerM is described, during which you will also
become familiar with the ImuAssistant build-in data recorder function.
Step 1 – Restore Default Setting
Before the test, a few settings must be done to make sure that TransducerM is properly configured.
Procedure Instruction Comment
1
TransducerM power on
2
Wait 15 seconds
To ensure the initialization procedure finishes.
3
Open ImuAssistant, scan and open
TransducerM
4
In ImuAssistant, Click 'Use Default
Setting'
This button can be found in section number 3 of Figure 8
5
Select the default settings for a
particular user scenario.
(Only for TransducerM TM200 series)
For TM100 series, the default setting will be loaded after clicking the ‘Use
Default Setting’ button.
For TM200 series, a pop-up window will show up, asking which scenario
best describes the intended user case.
Options of Default Settings Comment
► Ground vehicle: Car, AGV, Robot
Recommended option
for testing.
► Flying vehicle: Drone, UAV
Recommended option
for testing.
► Marine application: Boat, Ferry, UUV
Recommended option
for testing.
► Other applications:
with strong and continuous vibration
Not recommended for
testing. Only when you
fully understand how
'Auto Boot' works.
Refer to 'Boot Mode'.
► Other applications:
without strong and continuous vibration
Not recommend for
testing. Only when you
fully understand how
'Auto Boot' works.
Refer to 'Boot Mode'.
► Compatible Mode:
Use legacy Firmware V3.x.x default
configuration (Lower Performance)
Lower performance.
Not recommended for
high demanding usage.