Programming Instructions
Programming screen « INSTALLATION » Page 53/74
E04 Flowrate DI2
- Parameter identification, we find the parameter number identification (E04), type (Flowrate) and
associated sensor input (
DI2).
Dosing stop threshold OFF
- Enter the low flowrate level which the dosage of the parameter conditioned by this flowrate will be
cut. Here the threshold is disabled, current value (
OFF), dosages will not be cut by the flowrate.
Press to open the numeric keyboard and enter the desired value.
Low flowrate threshold 0 l/h
- Enter low flowrate level for dosage control. Here the current value is (0).
Press to open the numeric keyboard and enter the desired value.
High flowrate threshold (OFF – No control) OFF
- Enter high flowrate level for dosage control. Here the control function is disabled, current value
(
OFF).
Press to open the numeric keyboard and enter the desired value.
Save:
- When a change is made, the “SAVE” button appears (floppy icon), you must save your configuration
by pressing it.
b) « Sensors & parameters » version
This version is only available if the installation option “Condition the flow rates only to the parameter” is
disabled.
Flowrate threshold settings
E04 Flowrate DI2
Dosing stop threshold OFF l/h
Controlling of the dosing power
Low flowrate threshold 0 l/h
High flowrate threshold (OFF – No control) OFF l/h
Flowmeter settings
Parameters with assigned flow sensor
pH
Flowrate Free Chlorine
Salinity
Flowrate settings