Programming Instructions
Programming screen « INSTALLATION » Page 42/74
E01 pH PI1
- Parameter identification, includes information on parameter number (E01), type (pH) and associated
main sensor input (
PI1)
Mode Threshold
- Dosage mode selection, on this selection button we find the selected mode information (Threshold).
Press to modify.
High threshold 7,20 pH
- Enter the high threshold value. Here the value is (7,0).
Press to open the numeric keyboard and enter the desired value.
Low threshold 7,00 pH
- Enter the low threshold value. Here the value is (7,2).
Press to open the numeric keyboard and enter the desired value.
Basic load OFF % - Maximum time OFF min – Activation threshold 90 %
- See Hysteresis dosing mode in previous part.
Save:
- When a change is made, the “SAVE” button appears (floppy icon), you must save your configuration
by pressing it.
Threshold ↓
Rising action
Falling action
Time
Dosage
power
Time
Measure
Threshold ↑