Programming Instructions
Programming screen « INSTALLATION » Page 17/74
b) Digital input configuration [2231]
Example with the edition of a water circulation input.
Press to open the following screen.
« Standard » case
DI1 Function Water circulation
- Digital input operation mode selection, on this selection button we find the information of the input in
the process of modification (
DI1) and the currently selected function (Water circulation). Press to
change it.
Idle state contact NO
- Choice of idle state to be taken into account, this check box contains the information currently
selected (
NO).
Press to toggle NO (normally open) mode to NC (normally closed) mode.
Activation delay time 5 Second(s)
- Enter the time that the input must remain during its activation before the information is taken into
account. Here it is (
5) seconds.
Press to open the numeric keyboard and enter the desired value.
Adjustment possible from 0 to 240 Second(s)
Deactivation delay time
OFF Second(s)
- Same as before, but for reverse state.
To delete an input contact:
- You must select « NO » from the list of functions and save your configuration by pressing the “SAVE”
button.
Water circulation
Setting digital input
DI1
Function
Water circulation
Idle state contact
Activation delay time
Second(s)
Deactivation delay time
Second(s)