Installation Instructions

Installation and connections Page 27/67
Installation and starting instructions
11) Potential-free relay connections (FO1 et FO2)
The potential-free relay outputs can be used as alarm relays, regulation or be controlled in Timer mode
as required.
Use a 2-wire cable with a section appropriate for the voltage and
current.
Remove the protective sheath
Strip wires on 7mm
Pass the cable through a cable gland
Connect a cable on the midpoint COMMON (42) of the terminal
block
Connect the second cable on the WORK (41) of the terminal
block or on the REST (43) depending on the function to be
performed
Tighten the cable gland to seal.
Use a 2-wire cable with a section appropriate for the voltage and
current.
Remove the protective sheath
Strip wires on 7mm
Pass the cable through a cable gland
Connect a cable on the midpoint COMMUN (48) of the terminal
block
Connect the second cable on the WORK (47) of the terminal
block or on the REST (49) depending on the function to be
performed
Tighten the cable gland to seal
.
FO1
FO2