Installation Instructions
Installation and connections Page 27/67
Installation and starting instructions
11) Potential-free relay connections (FO1 et FO2)
The potential-free relay outputs can be used as alarm relays, regulation or be controlled in Timer mode
as required.
► Use a 2-wire cable with a section appropriate for the voltage and
current.
► Remove the protective sheath
► Strip wires on 7mm
► Pass the cable through a cable gland
► Connect a cable on the midpoint COMMON (42) of the terminal
block
► Connect the second cable on the WORK (41) of the terminal
block or on the REST (43) depending on the function to be
performed
► Tighten the cable gland to seal.
► Use a 2-wire cable with a section appropriate for the voltage and
current.
► Remove the protective sheath
► Strip wires on 7mm
► Pass the cable through a cable gland
► Connect a cable on the midpoint COMMUN (48) of the terminal
block
► Connect the second cable on the WORK (47) of the terminal
block or on the REST (49) depending on the function to be
performed
►
Tighten the cable gland to seal
.
FO1
FO2