Instructions for use T99000080-2
Starter
Eject Time – sets the time for a reverse voltage pulse to disengage
the starter.
Eject Voltage – sets the eject voltage in order disengage the clutch on
startup
Run Voltage – Sets the voltage for the starter during startup
RPM Stable – rpm adjust rate of starter
Engine Cooling
Sets the cooling rpm after shut down or when starter is manually run
using test functions.
*Please note that following a failsafe failure or flameout that the
motor will not automatically enter a cool down sequence. This is
because the ECU has no way of knowing the status of the motor
whether flame out, crash or other.
Other
Clear Battery used – reset the value to zero. This allows the pilot to
determine how much battery life is remaining.
Adjust Temp – Used to calibrate the temperature reading on the
engine. Unless there is an issue adjustments are not normally
needed.
Temp Unit – set to Fahrenheit or Centigrade
Pump Unit – set DC pump or BS pump
Firmware Version – Displays the current version firmware for the
following engine controls:
TCU – Turbine control Unit
ECU – Engine Control Unit
GSU – Ground Screen Unit