Instructions for use T99000080-2
Running Display
RPM Acceleration/Deceleeation Curve/Delay time
Higher values mean a faster rpm increase/decrease rate. Adjust
according to weather, Altitude (ASL) or other conditions which
require adjustments to delay time. It is best to select a value that is
lower than a setting that yields the fastest possible response time in
order to avoid a flame out.
Raise value to decrease response time, Lower value to increase
response time
Max RPM – Set maximum RPM
Idle RPM – set idle RPM
Min RPM – set stop RPM , if motor RPM falls below this setting,
motor will shutdown.
MaxTemp - Set maximum running temp.If motor exceeds this value,
ECU will automatically limit fuel in order to reduce the temp.
LowVolt – set low volt warning
Restart - Can be set “valid” for enable or“invalid” disabled, flame
out automatically restart or not.
Restart power pump – set power to pump on restart. Normal range
from 0.3 – 0.7 Volt
PumpLimit – This value is used to set the limit to the pump to a
reasonable limit and is based on observation of actual running
values. Set this value to 20% higher than what is observed on the
main screen. This prevents excess pump pressure.
IdlePumpStab – set pump stable delay on idle rpm, normaly SW60B
tubine set 5-8, SW120-210 set 3-5
Learn RC
This menu is to train the transmitter to the ECU.
Max – Throttle up, trim up
Idle – Throttle down, trim up
Min – Throttle down, trim down
FailSafeTime – set fail safe time in seconds
[BUS] Throttle cha – setup throttle channel if use BUS Mode input
[BUS] Switchcha – setup switch channel if use BUS Mode input and
switch startup function,if turn on this function ,ppm input will
invalid, need use BUS mode for input
TelemetryMode – set telemetry mode 1/1 for single engine mode