Instructions for use T99000080-2
Large font Running Screen
Press “C” to toggle between large screen and normal
Main menu – initial screen
From the initial screen, press “OK” key, click “C” to toggle back to
boot screen
StartUp – enter startup menu
Running – enter Running menu
Adjust RC – Train Radio to ECU
Starter – set starter power
Cooling – set cooling rpm
Other – enter other parameters menu
Test – enter Test menu
DataChart – running data records
Language - switchable Chinese or English
Start Up Screen
PumpVoltage - Set pump voltage Typical value is 0.4-0.5v
RPM StartUp Ramp – Set ramp profile starter , This parameter
adjusts the speed of the starter increase during the “Preheat to RPM
Off Starter” phase. Higher values mean a faster rpm increase.
Increase this value if the engine too hot duing preheat to rpm off
starter , and decrease it if flame out duing preheat to rpm of starter.
Pump StartUp Ramp - This parameter adjusts the speed of the fuel
increase during the “Fuel ramp” phase. Higher values mean a faster
fuel flow increase. Increase this value if the engine takes too long to
arrive to idle, and decrease it if the starts are too hot, with the engine
overshooting the idle speed.
GlowPlug – Set Glow Plug Voltage.
GasValve – Set the values of time of the gas fuel valve is open at
beginning of the ignition phase.
Ignition RPM – Set the RPM where ignition phase commences
Preheat RPM – Set the RPM value for preheat phase to begin.
RPM Off Starter – Set the RPM where the starter motor will
disengage.