Hint:
We recommend to use location strip no. 260-0020-00 for anti-twisting of the front bezel.
At momentary position the overturning force is max. 60 Ncm
Contacts: NC = Normally closed, NO = Normally open
Switching action: MA = Maintained action, M = Momentary action
Terminals: P = PCB terminal, S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Component layout from page 83, Mounting dimensions from page 84, Technical drawing from page 88, Circuit drawing from page 99
Selector switch actuator 2 positions 55 mm IP 65 52 mm 1 NC + 1 NO MA P 911-.700-WP 1 2 28 31 0.013
MP931-.700-WP 1 2 28 25 0.013
2 NC + 2 NO MA P 912-.700-WP 1 2 28 28 0.014
MP932-.700-WP 1 2 28 22 0.014
3 NC + 3 NO MA P 913-.700-WP 1 2 28 29 0.015
MP933-.700-WP 1 2 28 23 0.015
4 NC + 4 NO MA P 914-.700-WP 1 2 28 30 0.018
MP934-.700-WP 1 2 28 24 0.018
5 NC + 5 NO MA P 915-.700-WP 1 2 28 27 0.022
MP935-.700-WP 1 2 28 21 0.022
55 mm 1 NC + 1 NO MA S1 911-.700-W0 221310.013
MS1931-.700-W0 221250.013
2 NC + 2 NO MA S1 912-.700-W0 221280.014
MS1932-.700-W0 221220.014
3 NC + 3 NO MA S1 913-.700-W0 221290.015
MS1933-.700-W0 221230.015
4 NC + 4 NO MA S1 914-.700-W0 221300.019
MS1934-.700-W0 221240.019
5 NC + 5 NO MA S1 915-.700-W0 221270.023
MS1935-.700-W0 221210.023
0
Front protection
Mounting depth
Contacts
Switching action
Terminals
Typ-Nr.
Component layout
Mounting dimensions
Technical drawing
Circuit drawing
e
Maintained
90 °
Momentary
60 °