User's Manual

ITC2100-NA Operation and Service Manual Version 1.0
© SWISSPHONE Wireless AG
Page 80 of 129
6.8.3 Alarming / system message
6.8.3.1 Incoming jobs
The incoming alarm jobs are saved in a separate logging file and can be viewed at any time
by clicking the link Incoming jobs. Various filter options are available. Clicking on the button
"Delete file(s)" erases all log files. Warning: The files are irrevocably deleted.
From V4.2 on, the respective code word error rates are displayed. Example:
[-37dBm, CwER1=0/561 (0.0%), CwER2+=0/561 (0.0%)]
CwER1: Number of code words with only one bit error (100% correctible)
CwER2: Number of code words with bit errors above or equal to 2
Fig. 6-44: Incoming jobs
Field
Description
Files:
By clicking on the link "Broadcast Alarm" or "System message" the cor-
responding log file can be viewed, The size of both log files can be modi-
fied by clicking the link "Change filesize…" (do not set above 10kB). By
clicking on one of the small boxes (with a tick) and then on the button
Reload the display (lower half of the screen) is limited to the log that was
clicked.
Filter settings:
All: displays the total period of the logs selected in the field "Files"
Manual: displays the logs selected in the field "Files" within the period
defined in the field "Choose message:".