User's Manual
ITC2100-NA Operation and Service Manual Version 1.0
© SWISSPHONE Wireless AG
Page 67 of 129
6.6.2.3 Local Output
In order to print out or display the received data on a printer or monitor, there is an option of
doing this via the serial port (COM1) of the controller module. The serial port must have the
following setting:
Fig. 6-34: Configuration of the local output
Field
Description
Local Alarming:
See chapter 6.6.3.2 Local Alarming.
Protocol:
See chapter 6.6.3.2 Local Alarming.
Messaging:
See chapter 6.6.3.2 Local Alarming.
Local output:
Switch on ("COM 1") or switch off ("Disabled") the local out-
put. When switched on, received messages as defined in
the field "Rx Monitoring" are forwarded.
RX Monitoring:
Eavesdropper: The complete POCSAG radio traffic is moni-
tored and logged(also see Logging->RX/TX Monitoring).
Only base station: The POCSAG data for this single ITC is
monitored and logged (also see Logging->Alarming/System
message).
Note: Because the Controller only has a single serial interface (COM 1) available, either the
function "local alarming" or the function "local output" can be used.