6.5 Status Page
The status page looks virtually the same as the access page. The only difference is that
more information is available to the servicing technician, e.g. the base station name, alarm
ring number and the position number. In addition, the servicing technician can view the sta-
tus information in detail by clicking with the mouse but he or she cannot change or config-
ure it. This is done in the Configuration page.
The various statuses are identified in colour. The following basically applies:
Ok (green): The module is working correctly
Check state (yellow): The module is working correctly but should be checked
Error (red): The module is faulty
Note: As soon as the module error has been eliminated and the module is operating cor-
rectly, the status display can be set back to green (OK). This procedure is carried out via
the menu Logging in System statistic via the link Reset counters (see chapter 6.8.2.2). The
counter can also be requested and reset from a remote location via Digicom (Swissphone
network alarm controller software).