User's Manual
ITC2100-NA Operation and Service Manual Version 1.0
© SWISSPHONE Wireless AG
Page 19 of 129
5.3 Power Supply
The ITC2100-NA requires 90-264 VAC power supply. The maximum power consumption is
200W and 2.5A (AC). Much higher currents can flow during switch-on owing to the
switched-mode power supply unit. Follow the conventional wiring regulations for the country
concerned. The ITC2100-NA must be connected to the mains via a three-core cable and
the PE wire must have a minimum cross-sectional area of 1 mm
2
5.4 Fuses
The ITC2100-NA has two fuses, which should only be replaced by trained personnel. The
mains fuse is located inside the power supply and can only be replaced by Swissphone.
The battery supply has its own fuse located above the power supply switch on the front side
of the ITC2100-NA. The specifications of the individual fuses are as follows:
Mains fuse: T 4 A / 250 V (only replaceable by Swissphone)
Battery fuse: T 12.5 A / 250 V
5.5 Installation
As an option the ITC2100-NA can be mounted in a 19" rack. The space required by the
ITC2100-NA is 3U
4
(~13.5cm). The width corresponds to a 19'' plug-in module and the
depth is 315mm.
5.6 Electrical Connections
The electrical connections have to be made after installing the ITC2100-NA, i.e. in the rack.
These electrical connections are as follows:
Mains cable
VHF coaxial antenna cable (50 / N connector)
At master ITC: min. cat. 5 cable
At multi-master ITC: RS485 cable
Cable for I/O contacts
5.7 Ambient Conditions
The ITC2100-NA may be installed at any location suitable for electronic communication
equipment. However, the following values are not to be exceeded:
Operating temperature range: -25°C to +55°C
Relative humidity: max. 80%
4
U=height unit