User's Manual

ITC2100-NA Operation and Service Manual Version 1.0
© SWISSPHONE Wireless AG
Page 117 of 129
8 Module Replacement During Servicing (Only for Level 2
Service Partners!)
Note: This chapter describes the service activities at Service Level 2. These activities may
only be undertaken by skilled staff trained to Level 2 by Swissphone.
8.1 Important Notes
The ESD guidelines for the protection of electronic components against electro-static phe-
nomena must be observed in accordance with DIN EN 61340-5-1. Always touch the
ITC2100 housing with one hand first before handling the relevant module. This discharges
electrostatic voltage and so prevents damage to the electronic components.
Module replacement does not extend the existing guarantee or guarantee periods. The
module replacement does not renew guarantees or guarantee periods which have already
expired.
8.2 Replacing the Battery 12V 12Ah
8.2.1 Procedure
1) Shut down the ITC2100
2) Switch off the power supply (mains switch to position "0")
3) Disconnect the mains cable
4) Disconnect the old battery from the ITC2100
5) Connect the new battery to the ITC2100 (see chapter 5.10)
Warning: Ensure that the battery poles are correctly connected. The equipment is not
protected against false polarity.
6) Connect the mains cable
7) Switch on the ITC2100 (mains switch to position "1"), the ITC2100 will boot
8) Function control
Green LED of the power supply is on (=mains ok)
Green LED of the controller card is on
Test battery operation by pulling out the mains cable. The ITC2100 should continue
to funtion correctly.