These instructions are updated on a regular basis. Please visit our web site at http://www.swiftnets.com Copyright Swiftech 2005 – All rights reserved – Last revision date: 06-14-06- Information subject to change without notice – URL: http://www.swiftnets.com th Rouchon Industries, Inc., dba Swiftech – 1703 E. 28 Street, Signal Hill, CA 90755 – Tel. 562-595-8009 – Fax 562-595-8769 - E Mail: Swiftech@swiftnets.
Packing List QTY 1 1 1 1 8 1 1 1 ITEM APOGEE water-block, including hold-down plates (multi sockets and AM2), various processors mounting systems, and (2) hose clamps MCP350 pump, including mounting hardware and (2) 3/8” hose clamps MCRES-Micro, including mounting hardware, 3/8” hose-barb fittings, and (2) hose clamps MCR80-QP Radiator assembly, including pre-installed 80mm fan (without fan guards), mounting hardware, 12v to 7v adapter, and (2) hose clamps Feet 3/8” ID industrial grade PVC tubing Length
TABLE OF CONTENTS I. PLANNING ................................................................................................................................................... 4 1. General Guidelines .............................................................................................................................................. 4 2. Tube Routing.................................................................................................................................................
INTRODUCTION Congratulations on your purchase of a Swiftech™ H20-APEX liquid cooling system! This kit has been designed to facilitate the installation of the components with a minimum or no of case modifications. While all attempts have been made to make the installation of this system user friendly, please note that this system is intended for users that are well versed in installing computer components.
The following table contains examples on how to establish connections between the different elements of a cooling circuit based on multiple possible configurations. These are guidelines only, and may change depending on the relative position of the components inside your chassis.
3. 4. 1. Pump Reservoir RADIATOR INSTALLATION The MCR80-QP Radiator ships pre-assembled with our 80mm fan, as shown in figure 1. All you need to do is re-use the existing fan screws, or fan retention mechanism. An alternate installation is also possible as shown in figure 2, by using the provided M3.5mm x 30mm screws, going through the computer panel, though the fan, and to the radiator.
2. APOGEE WATER-BLOCK INSTALLATION One or more Patents pending This product is intended for expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your components. Swiftech™ assumes no liability whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions are subject to change without notice. Please visit our web site at www.swiftnets.com for updates.
Packing List COMPONENT ID COMPONENT DESCRIPTION QTY USAGE BHSC006C0-007SS 6-32 X 7/16 BUT HD CAP SS 4.00 WATER-BLOCK ASSEMBLY O-RING 3/32 B1000-133 O-RING 3/32 X 1 13/1 1.00 WATER-BLOCK ASSEMBLY APOGEE-H APOGEE WATERBLOCK HOUSING 1.00 WATER-BLOCK ASSEMBLY APOGEE-BRKT APOGEE HOLD-DOWN PLATE 1.00 WATER-BLOCK ASSEMBLY APOGEE-BP B1000-2.5X50 APOGEE BASE PLATE BUNA-N 70D BLACK O-RING 1.00 2.00 WATER-BLOCK ASSEMBLY FITTINGS PM4S-6BN 1/4" - 1/8 NPSM TO 3/8" ID 2.
Intel® Pentium® 4 Socket 478 Intel® Pentium® 4 Socket 478 Use hardware from the “common pack” ITEM NO. PART NUMBER 1 S478 2 apogee-assy APOGEE-H APOGEE-BP APOGEE-BRCKT O-RING-9557K473 1-4-straightx3-8-barb APOGEE-P4S478--HARDWARE 6-32-Acorn-nut 70927-368 6-32-nut LOCK-WASHER#6 FW140X250X0215FB BLK 91772A157-6-32x1.
Intel® Pentium® 4 and Pentium® D Socket LGA 775 Intel® Pentium® 4 and Pentium® D Socket LGA 775 Use hardware from the “common pack” ITEM NO. 1 2 2a 2b 3 3a 3b 3c 3d 3e 3f 3g 2b PART NUMBER LPGA 775 apogee-assy 92949A149 O-RING-9557K473 1-4-straightx3-8-barb O-RING_3-32 APOGEE-H APOGEE-BP APOGEE-BRCKT APOGEE-775-HARDWARE 6-32-Acorn-nut SPRING6 6-32-nut LOCK-WASHER#6 FW140X250X0215FB BLK 91772A157-6-32x1.5 12SWS0444 DESCRIPTION QTY.
Intel® Xeon™ Socket 603/604 400 and 533 MHz FSB motherboards Intel® Xeon™ Socket 603/604400 and 533 MHz FSB motherboards Use all parts from “common parts pack” except Philips screws: replace with the enclosed 6-32 1 5/8” long screws, instead of the 1 1/2” long screws supplied in the common parts pack. ITEM NO.
Intel® Xeon™ Socket 604 “Nocona” 800 MHz FSB motherboards Intel® Xeon™ Socket 604 “Nocona” 800 MHz FSB motherboards Use Intel Xeon “Nocona” separate hardware. ITEM NO. PART NUMBER 1 Nocona board mockup 2 spring-backplate 3 4 chassis STANDOFF-0.187 4-40 nylon retaining washer 5 SPACER-13LTS2501400697 6 90272A153-6-32x1-philips 7 apogee-assy APOGEE-H APOGEE-BP APOGEE-BRCKT O-RING-9557K473 1-4-straightx3-8-barb 3a 7a 7b DESCRIPTION QTY.
AMD® Athlon®, Duron®, MP, XP, Sempron® Socket 462 AMD® Athlon®, Duron®, MP, XP, Sempron® Socket 462 Use common hardware pack. Compatibility: Exclusively compatible with motherboards featuring mounting holes around the socket. ITEM NO. 1 2 2a 2b 3 3a 3b 3c 3d 3e 3f 3g PART NUMBER socket462 apogee-assy 92949A149 O-RING-9557K473 1-4-straightx3-8-barb APOGEE-H APOGEE-BP APOGEE-BRCKT APOGEE-462-HARDWARE 6-32-Acorn-nut SPRING6 6-32-nut LOCK-WASHER#6 FW140X250X0215FB BLK 91772A157-6-32x1.
AMD® 64, Sempron®, Opteron® Socket 754, 939, 940 AMD® 64, Sempron®, Opteron® Socket 754, 939, 940 ITEM NO. 1 2 3 4 5 6 Use separate AMD 754/939/940 hardware pack PART NUMBER DESCRIPTION 90272A153-6-32x1.00-philips 6-32 x 1" Philips screw washer-0148x0266x0040-91007A619 Lock Washer #6 x 0.
AMD® 64, FX, X2, Sempron®, Socket AM2 Remove the pre-installed hold-down plate first, as described on the next page. ITEM PART NUMBER 1 90272A153-6-32x1.00-philips 2 washer-0148x0266x0040-91007A619 3 apogee-assy-AM2 4 13RS040637 5 SOCKET AM2 DESCRIPTION QTY . Philips screw 4 Lock Washer #6 x 0.
The Apogee water-block ships pre-installed with the multi-socket hold-down plate. In order to install your Apogee with AMD’s AM2 socket, you will need to remove the existing hold-down plate and replace it with the AM2 model as follows: Step 1: loosen all 4 screws using the included hex key, and set aside the standard hold-down plate. Step 2: place the AM2 hold-down plate on the Apogee body, and fasten all four screws in cross pattern. You can now use your Apogee with AM2 socket.
3. RE-INSTALLING THE MOTHERBOARD Now that the APOGEE water-block is securely fastened to the motherboard, go-ahead and install the motherboard into the chassis, following the instructions provided in your motherboard installation guide. 4. PUMP INSTALLATION General Use The MCP350™ pump is a magnetically driven centrifugal pump featuring a 12 V DC brushless motor. It requires no maintenance when used with de-mineralized water and the appropriate anti-fungal additives.
5. MCRES-MICRO RESERVOIR INSTALLATION Installation • The MCRES-MICRO can be installed in any suitable location meeting its form factor requirements. For filling and bleeding purposes, it is preferable to hold or to install the MCRES-MICRO at the highest point of the liquid cooling loop. However, once filled and hermetically closed, the reservoir can be installed practically anywhere as long as it is kept upright as shown in figure 1.
6. .PREPARING THE TUBING Now that your radiator, water-block, pump and reservoir are in place, it is time to cut segments of tubing and connect the devices together. In addition to the supplied high quality vinyl tubing, your kit also comes with a 40” length of Smartcoils which, when extended provides a sufficient length to wrap 6 feet of tubing. Use of these coils is mandatory in order to prevent kinking and flattening of the tube over time.
Prior to fill-up the circuit, you will need to re-install your power-supply in order to start-up the pump during the fill procedure. You must be able to start the PSU without it being connected to the motherboard. While the Internet contains numerous references on how to use a paper-clip to shortout pin 13 and 14 of the 20 pin ATX connector as shown below, we nonetheless recommend instead using a power-supply tester.