User's Manual

Disable/enable messages
This command allows selective disabling/enabling of messages from the Tracker, as well as
setting parameters including message delivery preferences, controlling the GPIO1 pin, and
controlling the red and green LEDs.
$OP <?|p1=<val>[,p2=<val>[,...]]]*xx
Parameter
Description
?
Display current settings
DT=0|<rate>
Disable or set rate of $DT messages
GJ=0|<rate>
`Disable or set rate of $GJ messages
GN=0|<rate>
Disable or set rate of $GN messages
GS=0|<rate>
Disable or set rate of $GS messages
LG=<led_mode>
Set operating mode for green LED
LR=<led_mode>
Set operating mode for red LED
MD=I|P
Set msg delivery immediate (default) or polled
Returns one of:
Value
Description
$OP OK*xx
Parameters updated successfully
$OP ERR*xx
An error response
Notes:
The ? option allows reading back the current settings. This is a comma separated list of all
options. NOTE: Options are in alphabetical order, therefore as new options are added, they may
appear in the middle of the string. The user application should NOT rely on any given option
37