SDS

SAFETY DATA SHEET
PREMIER BUILDING SOLUTIONS, INC..
Page 10 of 14
Version: 1.1
Revision Date: 3/10/2015
XTRABOND 250 100% RTV SILICONE SEALANT
10
unlikely to occur from exposure to this product. Carbon black has been classified by the International Agency
for Research on Cancer (IARC) as possibly carcinogenic to humans (Group 2B) by inhalation. This product
contains carbon black in a non-respirable form. Inhalation of carbon black is unlikely to occur from exposure to
this product.
Target Organ Effects
Skin. Respiratory system. Eyes. Gastrointestinal tract (GI). Lungs.
Aspiration Hazard
No information available.
Numerical measures of toxicity
The following values are calculated based on chapter 3.1 of the GHS document
ATEmix (oral) = 11,867.00 mg/kg
12. ECOLOGICAL CONSIDERATIONS
Ecotoxicity
The environmental impact of this product has not been fully investigated.
Chemical Name Toxicity to Algae Toxicity to Fish
Toxicity to
Microorganisms
Daphnia Magna
(Water Flea)
Supplier Trade
Secret
96h LC50: = 2.2 mg/L
(Lepomis
macrochirus) 96h
LC50: = 2.4 mg/L
(Oncorhynchus
mykiss) 96h LC50: =
45 mg/L (Pimephales
promelas)
96h LC50: = 4720 mg/L
Supplier Trade
Secret
24h EC50: > 5600 mg/L
Persistence and Degradability
No information available.
Bioaccumulation
No information available
Other adverse effects
No information available.