SDS
  Product Name:      EXXSOL™ D60(S) FLUID 
  Revision Date:    18 Dec 2015 
  Page 8 of 17  
______________________________________________________________________________________________________________________ 
EXPOSURE LIMIT VALUES 
Exposure limits/standards (Note: Exposure limits are not additive) 
  Substance Name 
Form 
Limit/Standard 
Note 
Source 
Year 
NAPHTHA (PETROLEUM), 
HYDROTREATED HEAVY 
Vapour. 
RCP - 
TWA 
1200 mg/m3 
171 ppm 
Total 
Hydrocarb
ons 
ExxonMobil 
2009 
NOTE: Limits/standards shown for guidance only.    Follow applicable regulations. 
ENGINEERING CONTROLS 
The level of protection and types of controls necessary will vary depending upon potential exposure conditions. 
Control measures to consider: 
  Adequate ventilation should be provided so that exposure limits are not exceeded.    Use 
explosion-proof ventilation equipment. 
PERSONAL PROTECTION 
Personal protective equipment selections vary based on potential exposure conditions such as applications, 
handling practices, concentration and ventilation.    Information on the selection of protective equipment for use 
with this material, as provided below, is based upon intended, normal usage.     
Respiratory Protection:      If engineering controls do not maintain airborne contaminant concentrations at a level 
which is adequate to protect worker health, an approved respirator may be appropriate.    Respirator selection, 
use, and maintenance must be in accordance with regulatory requirements, if applicable.    Types of respirators 
to be considered for this material include:   
  Half-face filter respirator    Type A filter material. 