SDS
  Product Name:      EXXSOL™ D60(S) FLUID 
  Revision Date:    18 Dec 2015 
  Page 5 of 17  
______________________________________________________________________________________________________________________ 
Inappropriate Extinguishing Media:    Straight streams of water 
FIRE FIGHTING 
Fire Fighting Instructions:    Evacuate area.    Prevent run-off from fire control or dilution from entering streams, 
sewers or drinking water supply.    Fire-fighters should use standard protective equipment and in enclosed 
spaces, self-contained breathing apparatus (SCBA).      Use water spray to cool fire exposed surfaces and to 
protect personnel.   
Unusual Fire Hazards:    Combustible. 
Hazardous Combustion Products:      Incomplete combustion products, Oxides of carbon, Smoke, Fume 
FLAMMABILITY PROPERTIES   
Flash Point [Method]:    61C (142F) - 66C    (151F) 
Flammable Limits (Approximate volume % in air):   LEL:    0.7          UEL: 5.3 
Autoignition Temperature:   >200C    (392F) 
  SECTION 6 
ACCIDENTAL RELEASE MEASURES 
NOTIFICATION PROCEDURES 
In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable 
regulations. 
PROTECTIVE MEASURES 
Avoid contact with spilled material.    Warn or evacuate occupants in surrounding and downwind areas if 
required, due to toxicity or flammability of the material.    See Section 5 for fire fighting information.    See the 
Hazard Identification Section for Significant Hazards.    See Section 4 for First Aid Advice.    See Section 8 for 
advice on the minimum requirements for personal protective equipment. Additional protective measures may be 
necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders. 
For emergency responders:    Respiratory protection: half-face or full-face respirator with filter(s) for organic 