12 
Method: OECD Test Guideline 474  
Result: negative  
Remarks: Based on data from similar materials 
Carbon black: 
Genotoxicity in vitro: 
Test Type: Bacterial reverse mutation assay (AMES)  
Result: negative 
Carcinogenicity 
Not classified based on available information. 
Ingredients: 
Titanium dioxide: 
Species: Rat  
Application Route: inhalation (dust/mist/fume) 
Exposure time: 24 Months 
Method: OECD Test Guideline 453  
Result: positive  
Remarks: The mechanism or mode of action may not be relevant in humans. The substance is inextricably 
bound in the product and therefore does not contribute to a dust inhalation hazard.  
Carcinogenicity - Assessment:  
Limited evidence of carcinogenicity in inhalation studies with animals. 
Aluminum: 
Species: Rat  
Application Route: inhalation (dust/mist/fume) 
Exposure time: 86 weeks 
Result: negative 
IARC: Group 2B: Possibly carcinogenic to humans  
(Titanium dioxide CAS# 13463-67-7) 
(Carbon Black CAS# 1333-86-4) 
OSHA: No ingredient of this product present at levels greater than or equal to 0.1% is identified as a 
carcinogen or potential carcinogen by OSHA.  
NTP: No ingredient of this product present at levels greater than or equal to 0.1% is identified as a known or 
anticipated carcinogen by NTP. 
Reproductive toxicity 
Not classified based on available information. 