User manual
Encoding / Learn transmitter:
SHT-12 FS has his own ID just like any other SH-12 transmitter. In this way an appropriate receiver reponds only to specific
transmitters, which have been learned by the user. Therefor switch the receiver in a learn mode and trigger a transmission.
A receiver has to learn a transmitter before a communication can be built up.
Function selection
The transmission behaviour is defined by the 8-pin DIP switch. Each input can be configured in the push button mode and the switch
mode (see chapter 4). If the DIP switches 1-4 are in the position “ON”, the inputs T1-T4 are configured in the push button mode. If the
DIP switches 5-8 are configured in the position “ON”, the inputs T1-T4 are in the switch mode.
Push button mode and switch mode should never be active simultaneously. DIP switch n and DIP switch n+4 shold never be
in the position ON at the same time (e.g. DIP switch 1 and DIP switch 5).
Transmitter action DIP switch function selection receiver information Module output
Push button
mode
Connect T1 to GND 1=ON / 5 = OFF T1 OUT1
Connect T2 to GND 2=ON / 6 = OFF T2 OUT2
Connect T3 to GND 3=ON / 7 = OFF T3 OUT3
Connect T4 to GND 4=ON / 8 = OFF T4 OUT4
switch mode
Connect T1 to GND 5=ON / 1 = OFF T1 OUT1
Connect T2 to GND 6=ON / 2 = OFF T2 OUT2
Connect T3 to GND 7=ON / 3 = OFF T3 OUT3
Connect T4 to GND 8=ON / 4 = OFF T4 OUT4
Disconnect T1 and GND 5=ON / 1 = OFF T5 (Evaluation only with SHR-12 K4) OUT2 + OUT4
Disconnect T2 and GND 6=ON / 2 = OFF T6 (Evaluation only with SHR-12 K4) OUT2 + OUT3
Disconnect T3 and GND 7=ON / 3 = OFF T7 (Evaluation only with SHR-12 K4) OUT2 + OUT3 + OUT4
Disconnect T4 and GND 8=ON / 4 = OFF T8 (Evaluation only with SHR-12 K4) OUT1 + OUT2
Frequency change
In rare cases it is necessary to change the frequency because of interference from other devices. In this case switch to the second
frequency (f2 ) (see figure). Please note that the corresponding receiver should have the same frequency (see the receiver instruction).
6 Technical Data
Working frequency: f1 433,62 MHz; f2 434,22 MHz
Antenna: Integrated antenna
Supply voltage : 4,5…24 V DC; 12V AC
Current consumption: Stand By 0,1mA; Regular transmit mode 8,5 mA (average)
Ambient temperature: -20°C to +65°C
Connections: Screw terminals on the inside
Case: 130mm x 85mm x 37mm; IP54
Emetteur fixe UHF Mode d'emploi (D– GB – F)
Lisez ce mode d'emploi attentivement.
Il fait partie intégrante de ce produit. Il comprend des renseignements importants décrivant la manipulation et la mise en marche.
Pensez-y si ce produit est utilisé par un tiers et conservez cette notice pour une lecture ultérieure.
Nous déclinons toute responsabilité pour les dommages indirects résultant de l'utilisation, ainsi que pour dommages ou blessures
causés par une mauvaise manipulation ou le manque de respect des instructions en quel cas la garantie serait caduque.
La conception de l´appareil répond aux critères de compatibilité électromagnétique nationaux et européens. Les documents de
conformité sont déposés chez le producteur.
1 Règlementation d'application
L'émetteur fixe SHT- 12 FS peut être contrôlé par 4 contacts (maximum) libres de potentiel pour transmettre les signaux radio de
commutation codés à un destinataire approprié (par exemple, le SHR- 12 K4). La fonction déclenchée est dépendante du récepteur et
de son câblage.
La transmission radio présente toujours un risque de défaillance. Il y a lieu d´en tenir compte pour des applications
susceptibles de menacer la sécurité des personnes. Respectez impérativement ces instructions!
Il est proscrit de modifier ou de manipuler l'électronique ou les composants. L'utilisation de l'appareil est exonérée de taxes et
exempte d'inscription.