User's Guide

All rights reserved Suzhou Pairlink Network Technology Ltd.
- 5 -
2.Electrical Specifications
Recommended Operating Conditions
Parameter
Specification
Min.
Typical
Max.
Power Supply
2.7
3.3
3.6
Digital I/O Characteristic
Characteristics
Symbol
Specification
Min.
Typical
Max.
Input Low Voltage
VIL
-
-
0.8
Input High Voltage
VIH
2.0
-
-
RF Specifications
Parameter
Conditions
Min.
Target output
power
Max.
Unit
Receiver RF Specifications
Frequency range
-
2402
-
2480
MHz
RX sensitivity
b
-
-
-91.5
-
-
Maximum input
GFSK,1 Mbps
-
-
-20
dBm
Transmitter RF Specifications(TBD)
Frequency range
-
2402
-
2480
MHz
Class 1: GFSK TX power
-
7.79
-
dBm
a.Typical operating conditions are 3.3V operating voltage and 25°C ambient
temperature.
b.The receiver sensitivity is measured at BER of 0.1% on the device interface.