User's Manual
Table Of Contents
8
9. Do not plug or remove the battery when it is charged, Otherwise, a charging fault will occur, if
the yellow light of the battery controller is steady on. wait for about 10 minutes and the
charging will return to normal, If you need to plug in and out, you can manually turn off the
battery
The main input must meet the following requirement:
Parameter
Minimum
Typical
Maximum
Unit
Comments
Input voltage range
90
110/220
290
V
Input below AC 210V
charger output maximum
power will be reduced
Input frequency
45
50/60
65
Hz
Rated load
Input current
40
A
Input impulse current
60
A
Generator requirements are as follows:
Parameter
Minimum
Typical
Maximum
Unit
Comments
Input voltage range
210
220/230
290
V
Input below AC 210V
charger output maximum
power will be reduced
Input frequency
45
50/60
65
Hz
Rated load
Rated power
8.5KW
W
Output maximum power
9K—10KW
W