Owner's Manual
Out of calculation limits
Suunto uses state of the art memory and microprocessors, however, there are limita-
tions to the memory capacity of decompression calculations. Therefore Suunto must
limit the maximum saturation of tissues on Suunto HelO2 and limit the maximum bottom
times on dives performed using the dive computer. The bottom times include decom-
pression calculation. While it is highly unlikely that the following bottom times are
confronted by open-circuit divers, it is important to warn you of their possibility.
The same limits are used in the Suunto Dive Planner and so repetitive dives will be
checked while planning a dive because a dive plan must be created in any case.
Table 5.2. Possible decompression dive times
First deep-
stop
CeilingBottom timeDepthO
2%/He%
Gas mix
46 m33 m250 min60 m20/35Tx
65 m50 m260 min80 m15/50Tx
80 m61 m120 min100 m12/60Tx
96 m73 m90 min120 m10/60Tx
Descent at the rate of 10 m/min is included in the time. The times allow for a safe ascent
using the bottom gas all the way to the surface without exceeding tissue pressures.
If a diver violates these limits, the dive computer goes to an error mode and the rest
of the dive must be conducted using the diveplan on the slate.
35