Operating and Storage Temperatures
SM-16 Operating temperature 0° C to 40° C [32° F to 104° F]
Storage temperature -20° C to 50° C [-4° F to 122° F]
SM-36 Operating and storage temperature 0° C to 40° C [32° F to 104° F]
Technical Specifi cations
The Suunto depth gauge SM-16 complies with the prEN 13319 standard.
The tolerances for depth gauges are:
At 3m +0.8 / -0.4 m
At 6m +0.8 / -0.4 m
At 9m ±0.8 m
At 15m +1/ -1.2 m
At 30m +1/ -1.2 m
At 45m +1/ -1.5 m
At 60m +1 / -1.5 m
The SM-36 pressure gauges comply with the EN 250 standard.
The tolerances for pressure gauges, measured at decreasing pressure are:
At 40 bar ± 5 bar
At 100 bar ± 10 bar
At 200 bar ± 10 bar