9 Installing the sensor
For bigger pipe diameters (>200 mm) the sensor can be installed with
only a 100 mm insertion depth as alternative method. This allows one
sensor to be used for all pipe sizes.
Note: This 100 mm installation depth method requires a setting
through the Android app or the service software.
Insertion depth= x+ y+100
x = wall thickness of pipe
y = length of the ball valve
Calculation example:
A 12”-diameter pipe with the wall
thickness of 9 mm
An 87 mm-long ball valve
x=9 mm ; y=87 mm
Insertion depth
= 9 mm+ 87 mm+100 mm= 196 mm
18 S402