Operation Manual

Installation
7 Installation
S 415 is delivered with following components:
Qty. Description Item no.
1 S 415 Thermal mass flow meter
S695 4150
S695 4151
S695 4152
S695 4153
1 5 m cable with M8 connector and open ends A553 0136
1 Instruction manual No P/N
1 Calibration certificate No P/N
7.1 Installation considerations
In order to maintain the accuracy stated in the technical data, the sensor
must be installed inline and fitted to tubes with the same diameter.
The sensor is for indoor use only! At an outdoor installation, the sensor
must be protected from solar radiation and rain.
It is strongly recommend not to install S 415 permanently in wet
environment as it exists usually right after a compressor outlet.
7.2 Electrical connection
The flow sensor is equipped with two Connector plugs “A and “B”. By
default the sensor is delivered with one 5 m cable with a M8 connector
on one side and open wires on the other side. To operate the S 415 one
cable connection is sufficient however if the pulse output is to be used or
the supply and signal should be on separate cables a second connection
cable has to be ordered.