Datasheet

RG 1608 N - 102 - B - T5
Resistance Tolerance
Package
(
T1,T5,T10
)
Temperature Coefficient of Resistance
Resistance
(E-24: in a three-digit number,
E-96: in a four-digit number 4 digits for all RG3216)
Part Code
Dimensions
PART NUMBER
CHARACTERISTIC of Power Temperature Derating Curve
susumu group catalog
100
50
Ambient Temperature (C)
Rated Load (%)
-55 0 85 155
The result of each reliability test for 8000 hours
Load life test
High temperature
exposure test
Moisture and
life test
Temperature
cycle test
10
0.50
0.40
0.30
0.20
0.10
0.00
0.10
0.20
0.30
0.40
0.50
100 1000
Test time (h)
high temperature expouse test (155C)
Resistance change (%)
3000 10000
1k
sample:
RG1608 series
test conditions:
tenperature:155
C
no load n100
10k
56k
100k
330k
10
0.50
0.40
0.30
0.20
0.10
0.00
0.10
0.20
0.30
0.40
0.50
100 1000
Cycle
Temperature cycle test
Resistance change (%)
10000
sample:
RG1608 series
test conditions:
55C(30 min.)/room tem.(3 min.)/
125C(30 min.)/room tem.(3 min.)
n=50
10
0.50
0.40
0.30
0.20
0.10
0.00
0.10
0.20
0.30
0.40
0.50
100 1000
Test time (h)
Load life test (85%)
Resistance change (%)
3000 10000
1k
sample:
RG1608 series
test conditions:
temperature:85C
applied voltage:rated voltage
test period:one cycle as follow
90 min. on /30 min. off n=100
10k
56k
100k
330k
10
0.50
0.40
0.30
0.20
0.10
0.00
0.10
0.20
0.30
0.40
0.50
100 1000
Test time (h)
Moisture and life test (THB 85C 85%)
Resistance change (%)
3000 10000
1k
sample:
RG1608 series
test conditions:
temperature:85C, moisture:85%RH
applied power:1/10 rated power
test period one cycle as follow
90 min. on /30 min off n=50
10k
56k
100k
330k
56k
100k