User Manual

Influent Conc:
7.20E+04
microspheres/mL
Eff Conc 1:
<6.70E-01
Analysis:
3.0um Microspheres Filtration Efficacy (parasite)
Test Notes:
Parasite surrogate was not detected in the filtrate; Value represents the method's detection limit
for the amount of sample analyzed as per the method's standard reporting units.
pH:
7.8
Client ID 1: Survivor Pro Filter L610 #1
microspheres/mL % Reduct 1:
>99.9991
BCS Sample ID 1:
1805322
Test Water:
General Test Water
Hardness:
157.2
TDS:
208ppm
Flow rate:
429-594mL/min
Test Point:
Initial Filtration Efficacy of Parasites (Cryptosporidium and Giardia)
NTU:
0.2NTU
Log10 Reduct 1:
>5
Eff Conc 2:
<6.70E-01
microspheres/mL
% Reduct 2:
>99.9991
BCS Sample ID 2:
1805323
Log10 Reduct 2:
>5
Eff Conc 3:
<6.70E-01 microspheres/mL
% Reduct 3:
>99.9991
BCS Sample ID 3:
1805326
Log10 Reduct 3:
>5
Client ID 2: Survivor Pro Filter L610 #2
Client ID 3:
Personal Water Filter L600 #1
Pressure(psi):
NA
Pressure(psi):
NA
Pressure(psi):
-2.98
TOC:
0.4ppm
Temp:
22.2 C
Eff Conc 4:
<6.70E-01 microspheres/mL
% Reduct 4:
>99.9991
Client ID 4:
Personal Water Filter L600 #2
BCS Sample ID 4:
1805327
Log10 Reduct 4:
>5
Pressure(psi):
-2.78
Test Point Conclusion:
Pass
Final Report BCS ID 1805322, 1805323, 1805326, 1805327 Revision #0, 06/06/2018
4609 NW 6th Street, Ste. A, Gainesville, Florida 32609
BCS Laboratories, Inc. – Gainesville
www.microbioservices.com
Tel. (352) 377-9272, Fax. (352) 377-5630
FL DOH #E82924, ISO/IEC 17025:2005 L2422 (ANAB), PA DEP# 68-03950, EPA# FL01147
This report shall not be reproduced, except in full, without the written consent of BCS Laboratories
Client: Survivor Filter
Page 2 of 5
Project: Purifier Initial Parasite Filtration Efficacy Testing