Survivor Filter Report No.:102092758COL-002
Date: June 12, 2015 Page 8 of 8
GFT-OP-10b (12 April 2013).
Benchmark and Non-Standard test Report: Report must be reproduced in its entirety
Percent Reduction Values -Chemical
Chemical Challenge
Unit Type Mercury Cadmium Lead
Survivor Filter
TM
PRO 0.01 Micron Water
Purifier
99.5% 87% 93%
Chemical Challenge
Unit Type Mercury Cadmium Lead
Survivor Filter
TM
Triple Absolute
Filtration to 0.05 Microns
89% 88% 89%
Conclusion
The microbiological hypothesis has been accepted since the plate count values were well outside the 8%
measurement of uncertainty of the microbiological test method.
The chemical hypothesis has been accepted since the percent reduction is well outside the 40% uncertainty of the
chemical test method.