User Manual
1717 Arlingate Lane
Columbus, OH, 43228
Telephone: (614) 279-8090
Facsimile: (614) 279-4642
www.intertek.com
Survivor Filter Report No.:102092758COL-002
Date: June 12, 2015 Page 7 of 8
GFT-OP-10b (12 April 2013).
Benchmark and Non-Standard test Report: Report must be reproduced in its entirety
Raw Chemical Test Data
Test Parameter
Result
Units
Chemical Standards
Chemical Contaminant
Mercury
Cadmium
Lead
--
Challenge Concentration
8111
8358
8846
PPM
Survivor Filter
TM
Triple
Absolute Filtration to
0.05 Microns
Analysis Replicate 1
882
1054
1040
PPM
Analysis Replicate 2
8
41
1006
993
PPM
Average
862
1030
1017
PPM
Survivor Filter
TM
PRO
0.01 Micron Water
Purifier
Analysis Replicate 1
40
1080
596
PPM
Analysis Replicate 2
39
1056
584
PPM
Average
4
0
1068
590
PPM
Percent Reduction Calculations
Percent reduction calculated as follows-
Percent Reduction = (A-B) x 100
A
Where:
A is the number organism/chemical concentration before running through the filter.
B is the number organism/chemical concentration after running through the filter.
Percent Reduction Values -Microbiological
Bacterial Challenge
Viral Challenge
Unit Type E.coli S.aureus Phi-X174
Survivor Filter
TM
Triple Absolute
Filtration to 0.05 Microns
>99.9% >99.9% 99.9%
Bacterial Challenge
Viral Challenge
Unit Type E.coli S.aureus Phi-X174
Survivor Filter
TM
PRO 0.01 Micron
Water Purifier
>99.9% >99.9% >99.9%
Survivor Filter
Survivor Filter
Survivor Filter