Installation Guide
SureSill, HeadFlash and HeadFlash-Flex are Patented and Patent Pending Technologies made only by Suresill, Ltd.
SureSill
TM
, HeadFlash
TM
, HeadFlash-Flex
TM
, Wet-R-Dry
TM
, DrainShield
TM
, and SideFlash
TM
are the exclusive
trademarks
1
of SureSill, Ltd. © Copyright SureSill, Ltd. 2004 - 2016. All rights reserved.
20130417
EXTERIOR DOOR SOLUTIONS
EXTERIOR DOOR DRAIN DETAIL
1.
STEP DOWN LANDING – RECOMMENDED
SURESILL
TM
Sloped Sill Pan™
Finish Floor
Door
Door Sill
Sealant Joint
Sloped
2” Minimum
CONCRETE OR
SUBFLOOR
Masonry
Veneer
DEDICATED DRAIANGE PATH - FOR PROPER
DRAINAGE BEHIND MASONRY USE RAIN
SCREEN SUCH AS ENKADRAIN 9010
®
BY
COLBOND, Inc. APPLY 2” WIDE STRIPS
12”O.C.
Mortar Joint
Landing
Tiles or other finish
surface
Fig. 1 EXTERIOR DOOR WITH STEP-DOWN LANDING
With Masonry Veneer - Door Drain Detail
Step Down Landing should be minimum 2”.
Install SureSill™ System per SureSill Water Management Guide
Instead of Masonry Veneer, other exterior cladding can be installed, such as Stucco, Siding, etc.,
however, a Dedicated Drainage Path proper drainage should always be installed.