Installation Guide
STEP 2
Slots for
Fasteners
Install 12” wide
water-proofing (SAF
or similar) 6” above
plate and over any
sub-floor area.
© Copyright 2004 – 2016 SureSill, Ltd. All rights reserved.
Install assembled SureSill
TM
Sloped Sill
Pan™ plumb and leveled across entire
rough opening, and secure to rough
opening by fasteners in slots provided.
STEP 5
Install WRB in shingle fashion, including over jamb flashing
and head flashing. ALLOW FREE DRAINAGE FOR SURESILL™
SLOPED SILL PAN™ AND HEADFLASH™ DURING AND AFTER
CONSTRUCTION. PAINTING IS RECOMMENDED FOR THE SURFACES
EXPOSED TO EXTERIOR. APPLY FOAM TO THE INTERIOR SIDE TO SEAL
THE GAP BETWEEN THE FRAME/JAMB AND THE ROUGH OPENING ON
THREE SIDES (TWO VERTICAL AND ON TOP).
STEP 1
Install Drainage Skirt 6” above
plate over any sub-floor area. See
Sealing the Sill Pan STEP 1 DETAIL
Apply sealant on
concrete, sub- floor or
base plate and 6” up
the sides.
STEP 4
Install window or door per OEM instructions. See STEP 4 DETAIL Install
additional SAF at jambs (brick mold). Apply 3/8” bead of sealant behind
the HeadFlash
TM
.
Install HeadFlash
TM
head flashing.
Apply SAF over the HeadFlash
TM
STEP 3
Use self adhering flashing (SAF) on
rough jamb, over SureSill
TM
End Caps.
Apply adhesive sealant to jambs and
head.
Adhesive
Sealant
(over SAF
and head)
IMPORTANT: Seal the 1/8” gap behind window or door
threshold with sealant and tool it flat.
Back of the door/window casing should be grooved to
accommodate for the sill pan.
THE SURE
LEVEL OF
PROTECTION
Page 2 of 3
SureSill™ Water Management Guide
*1
NOTE:
SURESILL™ SLOPED SILL
PAN™ AND SURESILL™
HEADFLASH™ SHOULD BE
INSTALLED AT THE SAME TIME
A WINDOW OR DOOR IS BEING
INSTALLED.