Installation Guide
STEP 4 DETAIL 
To prevent air and water infiltration seal 
between the back of the sill pan and the back 
of the jamb/sill and between the jamb and the 
rough opening. 
Installation Details 
SureSill™ Water Management Guide
*1
SureSill, HeadFlash and HeadFlash-Flex are Patent Pending Technologies made only by Suresill, Ltd. SureSill
TM
, HeadFlash
TM
, HeadFlash-Flex
TM
, Wet-R-Dry
TM
, and DrainShield
TM
, are the exclusive trademarks of SureSill, Ltd. 
© Copyright 2004 – 2016 SureSill, Ltd. All rights reserved.                       WMG H 105 20071201R   Page 3 of 3 
.                            
STEP 4 
Apply S
S
S
u
u
u
r
r
r
e
e
e
S
S
S
i
i
i
l
l
l
l
l
l
B
B
B
o
o
o
n
n
n
d
d
d
TM 
2
2
2
0
0
0
0
0
0
0
0
0
 sealant at 
jambs and head. 
STEP 7 
Install waterproofing 
in shingle-fashion, 
including over jamb 
flashing and head 
flashing. 
Provide free drainage 
for SureSill. 
NOTE *1: Recommended rough opening 
size is ¾” larger then the window/door 
frame. This is a generic Water 
Management Guide and it is not 
intended to alter Window and Door 
Manufacturer’s (OEM) 
recommendations. Please notify SureSill 
prior to installation if any steps are 
contradictory to OEM’s installation 
instructions. SureSill recommends that 
OEM approves the rough opening size, 
the installation method and all products 
used prior to installation. 
SEALING AGAINST AIR AND WATER INFILTRATION 
FRONT SIDE 
BACK SIDE 
SILL PAN ASSEMBLY 
DETAIL REMOVE LABELS FROM CONTACT SURFACES. 
AS PART OF THE SILL PAN ASSEMBLY APPLY SEALANT 
ALONG THE EDGE OF END CAP. WITHOUT PROPER 
ASSEMBLY THE SILL PAN WILL LEAK. SURESILL™ IFS™ 
SHOULD BE INSTALLED AT THE SAME TIME A WINDOW OR 
DOOR IS BEING INSTALLED.  
1. APPLY CONTINUOUS BEAD OF 
SEALANT BETWEEN THE BACK 
EDGE OF THE SILL PAN AND THE 
SILL OR JAMB, AND BETWEEN THE 
BACK EDGE OF END CAPS AND 
THE JAMB TO PREVENT ANY AIR 
AND WATER INFILTRATION. 
2. APPLY CONTINUOUS LOW 
EXPANSION FOAM OR SEALANT 
BETWEEN THE JAMB AND THE 
ROUGH OPENING ON THREE SIDES 
(TWO VERTICAL SIDES AND ON 
TOP) TO PREVENT AIR AND WATER 
INFILTRATION. 
 NOTE *2 : THE BEAD OF SEALANT 
SHOULD BE CONTINUOUS AND TOOLED 
FLAT. SOME SEALANTS MAY HAVE 
ADVERSE REACTION WITH CERTAIN SELF 
ADHERING FLASHING PRODUCTS. 
PLEASE VERIFY COMPATIBILITY WITH 
THE MANUFACTURER. THE FOAM AND 
THE SEALANT SHOULD OVERLAP AND 
HAVE AN AIR-TIGHT JOINT. 
DOOR OR 
WINDOW 
ROUGH 
OPENING 
Sealing the Sill Pan to WRB 
STEP 1 DETAIL - Seal the front lip of the Sill Pan to WRB or to 
Drainage Skirt. Seal between the sill pan and the rough opening 
by applying sealant on the bottom of the rough opening and 6” 
on the sides as indicated. This should provide a barrier against 
both moisture and air infiltration between the sill pan and the 
rough opening. Use 5/8” thick bead of sealant. 
 6” 