Chapter 3: Planning The Installation
3.6 Booster Location
Select an indoor location for the BDA that meets the following criteria:
Wall or ceiling mounts are both acceptable.
Near a properly grounded 110VAC outlet.
Avoid in a tightly enclosed or overly hot spaces.
All power and warning lights are easily visible.
You can use the shortest cables to connect all antennas.
3.7 Accessories
The nal step in the planning process is to make sure you have all of the necessary accessories to complete the
installation. You will need all of the items listed in Chapter 1 of this manual plus some or all of the following:
Cable clips: Use these to secure the cables to interior and exterior walls/ceilings.
Appropriately rated sealant/caulking: Use this to waterproof the opening where the cable from the exterior antenna
enters the building, if needed.
Hand and/or power tools: As needed to complete the installation.
Personal Equipment (PPE): Use all PPE required by local codes and/or best practices to help ensure personal safety
during installation.
Note: You may need to obtain a permit from your local building department to install the BDA and antennas. Check
your local building and/or electrical codes.