User Manual

11
PROPRIETARY
4. Click Scan, this will provide the user with a list of available devices in the drop menu.
5. When you have chosen the desired device in the drop menu above the Scan button, press
connect.
6. The WMR will connect to the device and a new tab will be created in Acheron with that device.
Basic WMR Controls
The WMR basic controls are related to identifying and connecting with remote devices. The WMR can
scan and connect to remote devices it sees in the environment. For devices using Radio Frequency Power
excitation, an RFP must be energized for the remote radio to become powered. The WMR device also
allows the user to select the communications channel. This is useful for installers setting up multiple
remote devices that coexist in the environment.
The wireless module receiver will display a tab in the Main Plot Window when connected to the software.
The WMR has a few graph channels, including its internal temperature sensor, and a few channels with
information on RF performance and packet transmission performance. Temperature is displayed in the
Graph Window by default.
Similar to all other devices, hardware build information, firmware build information, and build date
information are displayed at the top of the display tab.